Watlow MINICHEF 2000 Shelf Timer Application User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 15
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
8 Watlow MINICHEF 2000 Specifications
Specifications (1032)
Control Mode
Single and dual heat channels, PID or on/off.
1
Microprocessor-based, programmable, reverse-acting
control outputs.
User-selectable embedded application software defines
operation of display, keys, inputs, outputs, timing action.
One-step auto-tuning, WatHelp diagnostics, WatCurve
temperature compensation.
Agency
CE approved:
89/336/EEC Electromagnetic Compatibility Directive
-EN 50081-1: Emissions
-EN 50082-1: Immunity
73/23/EEC Low-Voltage Directive
-EN 60730-1 and EN 60730-2-9: Safety
NSF Listed, Criteria 2.
5
AGA: UL tested to AGA standard Z21.23, UL File
#E43684.
UL and C-UL recognized, UL 197, 873, 991 and CSA
standard C22.2-24, File # E43684.
Operator Interface
Membrane overlay, contamination and water resistant,
(supplied by customer).
LED display, 5-digit, 0.56 in high, red.
Displays times, temperatures, user prompts and
diagnostic codes.
User-selectable time and temperature display formats.
Temperature display formats
—˚F or ˚C.
Time display formats—H:MM:SS, HH:MM, or MMM:SS.
8 discrete indicator LEDs, red.
6 tactile feedback keys.
Menu-driven operation and manual modes available.
WatHelp diagnostics.
Real-time clock option displays time of day.
Accuracy
Calibration accuracy and sensor conformity
2
: ± 2.0°F
for Type J thermocouple and RTD, ± 0.35% of span for
Type K and E thermocouples, ±1 LSD, 77°F ± 5°F
ambient and rated line voltage of ±10%.
Accuracy span: 1000°F (540°C) minimum.
Temperature stability: ± 0.15˚F/˚F (0.15˚C/˚C) change
in ambient typical.
Sensors/Inputs
Contact inputs, TTL compatible with internal pull-up
resistor, two available.
Thermocouple,
3
software selectable Type J, K or E,
32 to 1200°F. (Dual-channel applications require at least
one ungrounded thermocouple).
•RTD,
3
2- or 3-wire, platinum, 100, 500, 1000, at 0°C,
software selectable DIN or JIS curves, 0 to 1200°F
(3-wire will function as 2-wire).
Input A/D resolution: 15 bit.
Output Options
Solid-state relay, 0.4A, with or without contact suppres-
sion.
Switched dc signal, 4.5V to 5.25V, 30mA maximum
output, minimum load resistance > 150, non-isolated.
Audible Output Options
Switched dc signal, 4.5V to 5.25V, 30mA maximum
output, minimum load resistance > 150, non-isolated.
Internal audible alarm, 75dB at 10 cm.
Connectors
Sensor Input Terminal Strip
4
: RIACON, 6-position,
quick-connect.
Power Supply & Input/Output Terminal
4
: AMP,
15-position, quick-connect.
Power/Line Voltage
20.4 to 26.4VÅ (ac), 47 to 63Hz.
15VA maximum.
For CE applications, input power must be limited to
15W external to the control.
Program retention upon power failure via non-volatile
memory.
Battery/real-time clock option: 6-year lithium battery,
provides power backup upon power failure, operation
resumption after power recovery, ability to display time
of day.
Operating Environment
32 to 176°F (0 to 80°C), 0 to 90% RH, non-condensing.
Storage Temperature
-40 to 176°F (-40 to 80°C).
Mechanical
Case: polycarbonate Lexan with adjustable mounting
collar (vertical or horizontal orientation), designed for
mounting on 16-, 18-, 20- and 22-gauge panels.
Internal panel mounting requires a specified panel
cutout and four #6-32 studs or equivalent.
Overall width x height x depth: horizontal - 4.13 in x
3.25 in x 2.00 in; vertical - 3.25 in x 4.13 in x 2.00 in
(Assumes mating connectors are attached. Does not
include wire bundle space requirements.).
Vibration: 2g, 10 to 150Hz, applied in any one of three
axes.
Weight: 6.50oz maximum.
Program Storage
All non-embedded user and factory programs are
stored in non-volatile memory. Can be changed by
reprogramming.
Sample/Update Rates
1 input: 4Hz.
2 inputs: 4Hz.
PID: 1Hz.
Control outputs: 100Hz.
Display: 10Hz.
1
The MINICHEF 2000 controller is to be used in systems with an
external high temperature limiting device.
2
Thermocouple lead resistance of 200 causes < 1°C error. RTD, 22
gauge wire will not contribute more than 0.086°F error/ft.
3
Dual channel applications require either two thermocouple sen-
sors or two identical RTD sensor types.
4
For mating connector information, see Ordering Information
Accessory section.
5
Certified for thermometer accuracy (oven and hot food holding
applications from 32°F to 60°F) when used with RTD or type J thermo
couple probes.
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15

Comments to this Manuals