Watlow Series 145 User Manual

Browse online or download User Manual for Sensors Watlow Series 145. Watlow Series 145 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Series 145
Users Manual
Temperature Limit
1241 Bundy Boulevard, P.O. Box 5580, Winona, Minnesota USA 55987-5580
Phone: 507/454-5300, Fax: 507/452-4507, Internet: http://www.watlow.com
The Watlow Series 145 is a 1/16 DIN temperature limit
controller with a thermocouple or RTD sensor input. The
1/16 DIN case features a front panel that provides the
Series 145 with water and corrosion resistance.
The Series 145 is designed to meet the needs of a wide
range of safety applications. It is available with a wide
variety of thermocouple and RTD ranges.
The compact size of the limit allows more flexibility in
applications where space is a problem. The Series 145 has a
standard integral setpot and a front panel LED output
status indicator.
(1927)
Control Mode
High or low limit, factory selectable
Manual or automatic reset on power loss, factory selectable
Latching alarm with manual reset on over or under temperature
Operator Interface
Sealed membrane front panel
Integral set point
Dual temperature scale (°F and °C)
LED indication of output status
Dial scale calibrated to compensate for sensor
non-linearities
Integral reset switch
Input
Thermocouple or RTD available
Thermocouple with automatic cold junction compensation
Thermocouple may be isolated or grounded
2- or 3-wire RTD input, platinum 100, 500, or 1000 @ 0°C
calibrated for DIN 0.003850/°C curve
Sensor break protection de-energizes output
Output
Electromechanical relay, 3A, Form C, SPDT: 3A @ 240V~, 3A @
28VÎ (dc), resistive, 275VA pilot duty rated
Accuracy
Adjustable Set Point
Calibration accuracy: ±1% of span, at 77°F ±5°F (25°C ± 3°C)
ambient and rated line voltage ± 1%
Set point accuracy: ±3% of dial scale
Accuracy span: 1000°F (540°C) minimum
Fixed Set Point
Calibration accuracy: ±10°F/±6°C of setting, at 77°F ±5°F (25°C
±3°C) ambient and rated line voltage ±1%
Temperature Stability
Thermocouple: Typically 5µV/°F ambient (9µV/°C ambient) input
referenced
RTD: Typically 0.2°F/°F ambient (0.2°C/°C ambient)
Voltage Stability
±0.01% of span (min span of 1000°F or 540°C) per % of rated line
voltage
Agency Approvals
CE: EN61010 - Safety
EN61326 - Industrial Immunity, Class B Emissions
Installation Category 2, Pollution Degree 2
873, File #E43684
to C22.2 No. 24, File #E43684
Approved for use in commercial cooking applications
FM Class 3545, File #J.I.3008516
Terminals
Screw clamp terminal: 12-26 gauge wire
Power
120V~, +10%/-15%, 50/60 Hz
230V~ to 240~, +10%/-15%, 50/60 Hz
10VA maximum power
Operating Environment
32 to 131°F (0 to 55°C)
0 to 90% RH, non-condensing
Storage temperature: -4 to 185°F (-20 to 85°C)
Dimensions
Height: 2.1 in (55 mm)
Width: 2.1 in (55 mm)
Depth: 4.0 in (102 mm)
Behind panel: 3.50 in (89 mm)
Front panel: 0.5 in (13 mm)
Weight
0.7 lb (0.3 kg)
UL
®
is a registered trademark of Underwriters Laboratories, Inc.
Note: Specifications subject to change without notice.
Specifications
General Description
$5.00 Made in the U.S.A.
Printed on Recycled Paper
10% Postconsumer Waste
0600-0004-0009 Rev C
August 2000
Supersedes: 0600-0004-0009 Rev B
Registered Company
Winona, Minnesota USA
TOTAL
3 Year Warranty
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Series 145

Series 145User’s ManualTemperature Limit1241 Bundy Boulevard, P.O. Box 5580, Winona, Minnesota USA 55987-5580Phone: 507/454-5300, Fax: 507/452-4507, I

Page 2 - Dimensions

2 Watlow Series 145 User’s ManualFigure 2a — Series 145 dimensions.Figure 2b — Series 145 panel cutout.• Use the correct sensor type per the model n

Page 3 - 2- and 3-Wire RTD

3 Watlow Series 145 User’s ManualPower WiringThermocoupleFigure 3b — Thermocouple wiring.NOTE: When an external device with a non-isolated circuit c

Page 4 - System Example

4 Watlow Series 145 User’s ManualFigure 4 — System wiring examples.1234789101156Series 104TemperatureController104C-1601-11004 (+) 5 (-)120V~L1L2136

Page 5 - Declaration of Conformity

5 Watlow Series 145 User’s ManualDeclaration of ConformitySeries 145WATLOW WINONA1241 Bundy BoulevardWinona, Minnesota 55987 USADeclares that the f

Page 6 - 145 _ - _ _ _ _ - _ 000

Connect according to input wiring instructions.Remove power to the controller and the controllerfrom the system. Apply power to the system withthe con

Comments to this Manuals

No comments