34 EZwarePlus Programming Manual
3. Click the Outline tab. In the Attribute section, select the following:
Type: Normal
Direction: Up
Zero: 0 (the register value represented when the bar graph is minimum)
Span: 100 (the register value represented when the bar graph is maximum)
Bar width ratio (%): 30
4. In the Bar color/style section, click the Transparent checkbox. Leave the Bar and Bar style colors at their
default blue.
5. Leave the Target indicator Enable box unchecked.
6. In the Alarm indicators section, select the following:
Low limit: 25
High limit: 85
Low color: yellow (the bar graph color is yellow when the register value is below 25)
High color: red (the bar graph color is red when the register value is above 85)
7. Click the Shape tab. Leave the Use shape checkbox unchecked and click the Use picture checkbox.