Technical Reference
Temperature
ranges:
.
.
-100
1400°F
K
t/c:
-100
to
2500°F
R
t/c:
500 to
3200°F
RTD.
-99.9 to
9999°F
_*
or
-73 to
760°C
or
-73 to 1371
°C
or 260 to
1760°C
or
_-99.9
to 537.7%
T/C inputs must be ungrounded.
%RH ranges (on
channel
#2
only) and user selectable. Range limits are 0.0 to
.
100.0% RH Input types:
RTD: % RH
IS
based upon Channel
#1
RTD as dry bulb and Channel
#2
RTD
as
l
0-5/DC:’
Direct
%
RH
signal on Channel
#2.
Dual
RTD
input includes analog retransmit of input signal levels: -0.5 to
5.0VDC
for Temp
Dual
T/C
and 0 to
0.5VDC
for
%RH.
inp
LSD.
=
0
ut includes analog retransmit
of
input signal levels:
1.5625mV
per
Volts.
Calibration offset of input signals.
l RTD: ±10.0°F or °C.:
l T/C:
±10°
or
°C.
Outputs
l
Control outputs are two per channel: heat
&
cool (humidify
&
de-humidify) action.
l Solid state relay,
0.5A
@
24VAC
min,
253VAC
max. opto-isolated, zero cross
switching or,
l
DC switched open collector solid state switches,
10VDC,
5mA.
l
Auxiliary discrete ouputs are displayed as Event
#1
thru
#4
for each
channel and
are user selectable as:
l
Solid state relay,
0.5A
@
24VAC
min,
253VAC max, opto-isolated, zero cross
switching or,
l
DC switched open collector solid state switches,
10VDC,
5mA.
.
Eight event outputs programmed per step, or
l
Six event outputs programmed per step, an1 alarm output per channel.
Accuracy
l Calibration Accuracy and Sensor Conformity:
±
0.25% of span,
±
1 digit
1%
wet/
dry
%
RH) at
77°F
±
5°F
ambient rated line voltage
±
1%.
l Accuracy Span:
1000°F
or
540°C
minimum.
l
Temperature Stability:
l Voltage Stability:
±
±2µV
/
°F
ambient.
0.01%
of span
/
%
of rated line voltage.
Communlcatlons
l
Serial
data communications.
l
RS422A
or
RS-423A
(RS232C
Compatible) 1200 Baud.
l
Electrically isolated.
l All o
perator
indications and controls.
l
RS-
4
22 with ANSI X3.28 subparagraph
2.2-A.3
protocol,
RS-423
with
XON/XOFF
protocol.
Terminals
l 36 each
#6
screws on
3 barrier
strips.
l Communications:
DB-15
female receptacle.
Power
.
115/230VAC
±1
O%,
50/60Hz.
l
Data
retention
upon power failure via
Lithuim
battery.
l
Optional battery backup real time clock.
Operating
Environment
30 to 130°F/0-55°C.
l
O-9O%
RH,
non-condensing.
Dimensions
•Height: 6.0 in.
•Width: 6.0 in.
.
. Overall depth:
8.8
in:
l
Behind panel depth:
7.5 in.
l Weight:
4.5 lb.
Specifications,
Appendix
WATLOW Series
1500
User's
Manual